Sonde en acier inoxydable avec capteur exposé Foodcare
PRIX : SUR DEMANDE
Testeur de pH de la viande avec électrode spécialisée intégrée-HI981045
PRIX : SUR DEMANDE
Réf: KL_413334
Digital Flat Tip pH Electrode for Food Surfaces
PRIX : SUR DEMANDE
The HI14140 has a unique open junction design that resists clogging and the probe’s flat tip makes it ideal for pH measurements on food surfaces. This probe features a 3.5 mm connector designed exclusively to be used with Hanna Instruments edge® Tablet Meters.
- Open junction design resists clogging.
- Built-in temperature sensor for automatic compensation of measurements.
- Ideal for surface measurements of meat and food samples.
Disponible sur commande
3
People watching this product now!
UGS :
KL_413334
Catégorie : Électrodes
Description
Built-In Microchip
The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter.
Low Temperature Glass Formulation
The glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. The HI14140 is suitable to use with samples that measure from 0 to 50°C.
Flat Tip
A flat tip is recommended to optimize surface contact for measurement on food products and samples that cannot easily be penetrate. Additionally, the recessed flat tip is easy to clean and prevents food solids from collecting on the sensor.
Glass Body
The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.
Open Junction Reference
Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable food measurements.
Digital 3.5 mm Connector
Plugging an electrode in has never been simpler; no alignments or broken pins, simply connect the 3.5 mm plug and begin. Digital electrodes are automatically recognized.
Specifications
| Specification Name | Detail |
|---|---|
| SKU | HI14140 |
| Description | digital pH electrode |
| Reference | single, Ag/AgCl |
| Junction / Flow Rate | open |
| Electrolyte | viscolene |
| Max Pressure | 0.1 bar |
| Range | pH: 0 to 12 |
| Recommended Operating Temperature | 0 to 50°C (32 to 122°F) |
| Tip / Shape | flat |
| Temperature Sensor | yes |
| Matching Pin | no |
| Amplifier | yes |
| Body Material | glass |
| Cable | 1 m (3.3’) |
| Recommended Use | surfaces |
| Connection | 3.5 mm connector |
Informations complémentaires
| Marques |
HANNA INSTRUMENTS |
|---|
Contacter nous
ENVOYEZ-NOUS UN MESSAGE
INFORMATIONS DE CONTACT
Que vous cherchiez des réponses, que vous souhaitiez résoudre un problème, que vous ayez besoin d’aide ou que vous souhaitiez simplement nous faire part de vos commentaires, vous trouverez des réponses à vos questions.
Note 0 sur 5
0 reviews
Note 5 sur 5
0
Note 4 sur 5
0
Note 3 sur 5
0
Note 2 sur 5
0
Note 1 sur 5
0
Soyez le premier à laisser votre avis sur “Digital Flat Tip pH Electrode for Food Surfaces” Annuler la réponse
Vous devez être connecté pour publier un avis.
Produits similaires
Électrode de pH au yogourt Foodcare (à utiliser avec HI99164)- FC2133
SKU:
KL_656324
Available on backorder
PRIX : SUR DEMANDEElectrode de pH numérique Corps en PVDF Foodcare pour produits laitiers FC2020
SKU:
KL_217776
Available on backorder
PRIX : SUR DEMANDEÉlectrode de pH pour les mesures directes de fromage (à utiliser avec HI99165) – FC242D
SKU:
KL_956857
Available on backorder
PRIX : SUR DEMANDEÉlectrode pH avec micro ampoule et connecteur BNC – HI1083B
SKU:
KL_275573
Available on backorder
PRIX : SUR DEMANDEElectrode pH pour mesures directes dans le fromage (pour HI98165) – FC2423
SKU:
KL_565788
Available on backorder
PRIX : SUR DEMANDEÉlectrode pH pour semi-solides (FoodCare Corps PVDF) – FC200S
SKU:
KL_865421
Available on backorder
PRIX : SUR DEMANDESonde à Thermocouple De Type K à Pénétration Ultra-Rapide Avec Poignée Foodcare
SKU:
KL_926173
Available on backorder
PRIX : SUR DEMANDESonde de thermocouple à pénétration (type T ultra-rapide)- FC767C1
SKU:
KL_893672
Available on backorder
PRIX : SUR DEMANDE
Produits Chimiques


Avis